4 Pole Contactors

  • AF16-22-00-13 – 18A 2N/O+2N/C Main Poles

    £31.24 Ex VAT

    ABB 4 Pole contactor 18A 2N/O+2N/C Main Poles AF16-22-00-13

    Contactor Rating : 18Amp AC3 – 30Amp AC1 – 15KW – 20HP
    2N/O+2N/C Main Poles – Coil Voltage 100V – 250V AC/DC

    AF16 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces…). AF… contactors include an electronic coil interface accepting a wide control voltage Uc min. … Uc max. Only four coils cover control voltages between 24…500 V 50/60 Hz or 20…500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF… series 4-pole contactors are of the block type design. – Main poles and auxiliary contact blocks: 4 N.O. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) – Control circuit: AC or DC operated – Accessories: a wide range of accessories is available.

    Add to basket Show details
  • AF16-40-00-13 – 18A 4N/O Main Poles

    £32.93 Ex VAT

    ABB 4 Pole contactor 18A 4N/O Main Poles AF16-40-00-13
    Contactor Rating : 18Amp AC3 – 30Amp AC1 – 15KW – 20HP
    4N/O Main Poles – Coil Voltage 100V – 250V AC/DC

    AF16 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces…). AF… contactors include an electronic coil interface accepting a wide control voltage Uc min. … Uc max. Only four coils cover control voltages between 24…500 V 50/60 Hz or 20…500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF… series 4-pole contactors are of the block type design. – Main poles and auxiliary contact blocks: 4 N.O. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) – Control circuit: AC or DC operated – Accessories: a wide range of accessories is available.

    Add to basket Show details
  • AF26-22-00-13 – 26A 2N/O+2N/C Main Poles

    £39.97 Ex VAT

    ABB 4 Pole contactor 26A 2N/O+2N/C Main Poles AF26-22-00-13

    Contactor Rating : 26Amp AC3 – 45Amp AC1 – 7.5KW – 10HP
    ?2N/O+2N/C Main Poles – Coil Voltage 100V – 250V AC/DC

    AF16 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces…). AF… contactors include an electronic coil interface accepting a wide control voltage Uc min. … Uc max. Only four coils cover control voltages between 24…500 V 50/60 Hz or 20…500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF… series 4-pole contactors are of the block type design. – Main poles and auxiliary contact blocks: 4 N.O. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) – Control circuit: AC or DC operated – Accessories: a wide range of accessories is available.

    Add to basket Show details
  • AF26-40-00-13 – 26A 4N/O Main Poles

    £55.18 Ex VAT

    ABB 4 Pole contactor 26A 4N/O Main Poles AF26-40-00-13

    Contactor Rating : 26Amp AC3 – 45Amp AC1 – 7.5KW – 10HP
    ?4N/O Main Poles – Coil Voltage 100V – 250V AC/DC

    AF16 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces…). AF… contactors include an electronic coil interface accepting a wide control voltage Uc min. … Uc max. Only four coils cover control voltages between 24…500 V 50/60 Hz or 20…500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF… series 4-pole contactors are of the block type design. – Main poles and auxiliary contact blocks: 4 N.O. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) – Control circuit: AC or DC operated – Accessories: a wide range of accessories is available.

    Add to basket Show details
  • AF38-22-00-13 – 38A 2N/O+2N/C Main Poles

    £77.15 Ex VAT

    ABB 4 Pole contactor 38A 2N/O+2N/C Main Poles AF38-22-00-13

    Contactor Rating : 38Amp AC3 – 55Amp AC1 – 18.5KW – 20HP
    ?2N/O & ?2N/C Main Poles – Coil Voltage 100V – 250V AC/DC

    AF16 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces…). AF… contactors include an electronic coil interface accepting a wide control voltage Uc min. … Uc max. Only four coils cover control voltages between 24…500 V 50/60 Hz or 20…500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF… series 4-pole contactors are of the block type design. – Main poles and auxiliary contact blocks: 4 N.O. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) – Control circuit: AC or DC operated – Accessories: a wide range of accessories is available.

    Add to basket Show details
  • AF38-40-00-13 – 38A 4N/O Main Poles

    £101.06 Ex VAT

    ABB 4 Pole contactor 38A 4N/O Main Poles AF38-40-00-13

    Contactor Rating : 38Amp AC3 – 55Amp AC1 – 18.5KW – 20HP
    ?4N/O Main Poles – Coil Voltage 100V – 250V AC/DC

    AF16 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces…). AF… contactors include an electronic coil interface accepting a wide control voltage Uc min. … Uc max. Only four coils cover control voltages between 24…500 V 50/60 Hz or 20…500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF… series 4-pole contactors are of the block type design. – Main poles and auxiliary contact blocks: 4 N.O. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) – Control circuit: AC or DC operated – Accessories: a wide range of accessories is available.

    Add to basket Show details