• AF09-30-10-14 – 250V-500V AC/DC 9A 3P N/O Auxiliary

    £18.61 Ex VAT

    ABB – 9A 3P N/O Auxilliary
    Contactor Rating : 9Amp AC3 – 25Amp AC1 – 4KW – 5HP 
    3Pole + N/O Auxilliary – Coil Voltage 250V – 500V AC/DC

    ?AF09 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads.

    Features

    • AF contactors include an electronic coil interface providing reduced pull-in and holding consumption, particularly for AC control circuits Only four coils are needed to cover control voltages between 24…500 V 50/60 Hz or 20…500 V DC.
    • AF offer extended operating limits and are suitable worldwide for different control voltages. e.g.: the coil 100…250 V 50/60 Hz – DC is suitable for Europe (230 V 50 Hz) and for North America (120 V 60 Hz and 208 V 60 Hz).
    • AF contactors can manage large control voltage variations
    • AF contactors equipped with a 24…60 V 50/60 Hz – 20…60 V DC coil allow direct control by 24 V DC 500 mA PLC-output
    • AF contactors withstand short voltage dips and voltage sags (SEMI F47-0706 compliance)
    • AF contactors have built-in surge protection and do not require additional surge suppressors.

    Applications
    For Controlling Power Circuits Up To 690 VAC And 220 VDC, For Controlling 3-Phase Motors, Non-Inductive Or Slightly Inductive Loads. A-Line contactors are mainly used for controlling 3-phase motors and for controlling power circuits corresponding to their operating characteristics up to 690 and even 1000 VAC. and 440 VDC. All AF contactors can be assembled side by side. The add-on auxiliary contacts are suitable for low level currents.
     

    Add to basket Show details
  • AF16-30-10-14 – 250V-500V AC/DC 18A 3P N/O Auxiliary

    £23.39 Ex VAT

    ABB – 12A 3P N/O Auxilliary
    Contactor Rating : 18Amp AC3 – 30Amp AC1 – 7.5KW – 10HP
    3Pole + N/O Auxilliary – Coil Voltage 250V – 500V AC/DC

    ?AF09 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads.

    Features

    • AF contactors include an electronic coil interface providing reduced pull-in and holding consumption, particularly for AC control circuits Only four coils are needed to cover control voltages between 24…500 V 50/60 Hz or 20…500 V DC.
    • AF offer extended operating limits and are suitable worldwide for different control voltages. e.g.: the coil 100…250 V 50/60 Hz – DC is suitable for Europe (230 V 50 Hz) and for North America (120 V 60 Hz and 208 V 60 Hz).
    • AF contactors can manage large control voltage variations
    • AF contactors equipped with a 24…60 V 50/60 Hz – 20…60 V DC coil allow direct control by 24 V DC 500 mA PLC-output
    • AF contactors withstand short voltage dips and voltage sags (SEMI F47-0706 compliance)
    • AF contactors have built-in surge protection and do not require additional surge suppressors.

    Applications
    For Controlling Power Circuits Up To 690 VAC And 220 VDC, For Controlling 3-Phase Motors, Non-Inductive Or Slightly Inductive Loads. A-Line contactors are mainly used for controlling 3-phase motors and for controlling power circuits corresponding to their operating characteristics up to 690 and even 1000 VAC. and 440 VDC. All AF contactors can be assembled side by side. The add-on auxiliary contacts are suitable for low level currents.
     

    Add to basket Show details
  • AF12-30-10-14 – 250V-500V AC/DC 12A 3P N/O Auxiliary

    £23.39 Ex VAT

    ABB – 12A 3P N/O Auxilliary
    Contactor Rating : 12Amp AC3 – 28Amp AC1 – 5.5kw – 7.5HP
    3Pole + N/O Auxilliary – Coil Voltage 250V – 500V AC/DC

    ?AF09 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads.

    Features

    • AF contactors include an electronic coil interface providing reduced pull-in and holding consumption, particularly for AC control circuits Only four coils are needed to cover control voltages between 24…500 V 50/60 Hz or 20…500 V DC.
    • AF offer extended operating limits and are suitable worldwide for different control voltages. e.g.: the coil 100…250 V 50/60 Hz – DC is suitable for Europe (230 V 50 Hz) and for North America (120 V 60 Hz and 208 V 60 Hz).
    • AF contactors can manage large control voltage variations
    • AF contactors equipped with a 24…60 V 50/60 Hz – 20…60 V DC coil allow direct control by 24 V DC 500 mA PLC-output
    • AF contactors withstand short voltage dips and voltage sags (SEMI F47-0706 compliance)
    • AF contactors have built-in surge protection and do not require additional surge suppressors.

    Applications
    For Controlling Power Circuits Up To 690 VAC And 220 VDC, For Controlling 3-Phase Motors, Non-Inductive Or Slightly Inductive Loads. A-Line contactors are mainly used for controlling 3-phase motors and for controlling power circuits corresponding to their operating characteristics up to 690 and even 1000 VAC. and 440 VDC. All AF contactors can be assembled side by side. The add-on auxiliary contacts are suitable for low level currents.
     

    Add to basket Show details
  • AF26-30-00-14 – 250V-500V AC/DC 26A 3Pole

    £39.97 Ex VAT

    ABB – 26A 3P N/O Auxilliary
    Contactor Rating : 26Amp AC3 – 45Amp AC1 – 15KW – 20HP  3Pole
    3Pole + N/O Auxilliary – Coil Voltage 250V – 500V AC/DC

    ?AF09 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads.

    Features

    • AF contactors include an electronic coil interface providing reduced pull-in and holding consumption, particularly for AC control circuits Only four coils are needed to cover control voltages between 24…500 V 50/60 Hz or 20…500 V DC.
    • AF offer extended operating limits and are suitable worldwide for different control voltages. e.g.: the coil 100…250 V 50/60 Hz – DC is suitable for Europe (230 V 50 Hz) and for North America (120 V 60 Hz and 208 V 60 Hz).
    • AF contactors can manage large control voltage variations
    • AF contactors equipped with a 24…60 V 50/60 Hz – 20…60 V DC coil allow direct control by 24 V DC 500 mA PLC-output
    • AF contactors withstand short voltage dips and voltage sags (SEMI F47-0706 compliance)
    • AF contactors have built-in surge protection and do not require additional surge suppressors.

    Applications
    For Controlling Power Circuits Up To 690 VAC And 220 VDC, For Controlling 3-Phase Motors, Non-Inductive Or Slightly Inductive Loads. A-Line contactors are mainly used for controlling 3-phase motors and for controlling power circuits corresponding to their operating characteristics up to 690 and even 1000 VAC. and 440 VDC. All AF contactors can be assembled side by side. The add-on auxiliary contacts are suitable for low level currents.
     

    Add to basket Show details
  • AF30-30-00-14 – 250V-500V AC/DC 32A 3Pole

    £61.57 Ex VAT

    ABB – 26A 3P N/O Auxilliary
    Contactor Rating : 32Amp AC3 – 50Amp AC1 – 15KW – 20HP
    3Pole + N/O Auxilliary – Coil Voltage 250V – 500V AC/DC

    ?AF09 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads.

    Features

    • AF contactors include an electronic coil interface providing reduced pull-in and holding consumption, particularly for AC control circuits Only four coils are needed to cover control voltages between 24…500 V 50/60 Hz or 20…500 V DC.
    • AF offer extended operating limits and are suitable worldwide for different control voltages. e.g.: the coil 100…250 V 50/60 Hz – DC is suitable for Europe (230 V 50 Hz) and for North America (120 V 60 Hz and 208 V 60 Hz).
    • AF contactors can manage large control voltage variations
    • AF contactors equipped with a 24…60 V 50/60 Hz – 20…60 V DC coil allow direct control by 24 V DC 500 mA PLC-output
    • AF contactors withstand short voltage dips and voltage sags (SEMI F47-0706 compliance)
    • AF contactors have built-in surge protection and do not require additional surge suppressors.

    Applications
    For Controlling Power Circuits Up To 690 VAC And 220 VDC, For Controlling 3-Phase Motors, Non-Inductive Or Slightly Inductive Loads. A-Line contactors are mainly used for controlling 3-phase motors and for controlling power circuits corresponding to their operating characteristics up to 690 and even 1000 VAC. and 440 VDC. All AF contactors can be assembled side by side. The add-on auxiliary contacts are suitable for low level currents.
     

    Add to basket Show details